Z80 Instruction Set UM008007-0715
172
Z80 CPU
User Manual
Condition Bits Affected
S is set if most-significant bit of the Accumulator is 1 after an operation; otherwise, it is
reset.
Z is set if the Accumulator is 0 after an operation; otherwise, it is reset.
H: see the DAA instruction table on the previous page.
P/V is set if the Accumulator is at even parity after an operation; otherwise, it is reset.
N is not affected.
C: see the DAA instruction table on the previous page.
Example
An addition operation is performed between 15 (BCD) and 27 (BCD); simple decimal
arithmetic provides the following result:
15
+
27
42
The binary representations are added in the Accumulator according to standard binary
arithmetic, as follows:
0001 0101
+ 0010
0111
0011 1100 = 3C
The sum is ambiguous. The DAA instruction adjusts this result so that the correct BCD
representation is obtained, as follows:
0011 1100
+ 0000
0110
0100 0010 = 42