WATCH-DOG TIMER
The Watch-Dog Timer (WDT) is a retriggerable one-shot
16-bit timer that resets the device
if it reaches its terminal
count. The
WDT is driven by the XTAL2 clock pin. To pro-
vide the longer time-out periods required in applications,
the watch-dog timer is only updated every 64th clock cycle.
When operating in the
RUN or HALT modes, a WDT time-
out reset is functionally equivalent to an interrupt vectoring
the PC to
0020H, and setting the WDT flag to 1. Coming
out of
RESET, the WDT is fully enabled with its time-out
value set at minimum, unless otherwise programmed during
the first instruction. Subsequent executions of the
WDT in-
struction reinitialize the watch-dog timer registers (
C2h and
C3h) to their initial values as defined by bits D6, D5, and
D4 of the TCTLHI register. The WDT cannot be disabled ex-
cept on the first cycle after
RESET and when the device en-
ters
STOP mode.
The
WDT instruction should be executed often enough to
provide some margin of time to allow the
WDT registers to
approach
0. Because the WDT time-out periods are rela-
tively long, a
WDT RESET occurs in the unlikely event that
the
WDT times out on exactly the same cycle that the WDT
instruction is executed.
RESET clears both the WDT and SMR flags. A WDT time-
out sets the
WDT flag, and the STOP instruction sets the
SMR flag. This function enables software to determine
whether a
WDT time-out or a return from STOP mode oc-
curred. Reading the
WDT and SMR flags does not reset the
flag to
0; therefore, the user must clear the flag via software.
Note: Failure to clear the SMR flag can result in unexpected
behavior.
Figure 11. TCTLHI Register for Control of WDT
D7 D6 D5
D4
D3 D2 D1
D0
0C1
TCTLHI
Reserved (must be 0)
0 = STOP mode enabled
1 = STOP mode disabled*
D6
D5
D4 WDT TIMEOUT VALUE
----
----
---- --------------------------------
0
0
0
Disabled
0
0
1
65,536
TpC*
0
1
0
131,072
TpC
0
1
1
262,144
TpC
1
0
0
524,288
TpC
1
0
1
1,048,576
TpC
1
1
0
2,097,152
TpC
1
1
1
8,388,608
TpC
(XTAL clocks to time-out)
1 = WDT enabled in HALT mode*
0 = WDT disabled in HALT mode
*Designates the default value after RESET.