UM024002-0512 The Z8051 On-Chip Debugger
Z8051 On-Chip Debugger and In-System Programmer
User Manual
46
Bank
The devices in the Z8051 Series use a linear addressing method, and display page units in
the 64 KB range. To overcome this 64 KB limit, the user can employ banked addresses, in
which a bank is the upper 4 bits of a 20-bit address.
Goto
Click the Goto button to view memory locations in any 16-bit segments within the
0000h–FFFFh address range in the XDATA Dump window or edit these memory loca-
tions by entering an address in hexadecimal format. See the example in Figure 51.
Figure 50. Using the XDATA Dump Function, #2 of 2
Figure 51. The XDATA Dump Function’s Goto/Input Dialog