SLLX Instruction UM018809-0611
156
ZNEO
®
CPU Core
User Manual
SLLX
Definition
Shift Left Logical, Extended
Syntax
SLLX dst, src
Operation
Description
The destination operand contents shift left logical by the number of bit positions (0–31) specified
in bits [4:0] of the source operand. On each bit shift iteration, the value of the most significant bit
moves into the Carry (
C) flag, and Bit 0 clears to 0.
The source register is cleared, and bits shifted out of the destination are shifted into the source
register. This instruction is generated by using the Extend prefix,
0007H, with the SLL opcode.
Flags
76543210
C Z S V B CIRQE IRQE
* * * *0–––
Legend
C = Set to 1 if the last bit shifted out of the destination register is 1; otherwise set to 0.
Z = Set to 1 if the 32-bit destination register contains zero; otherwise set to 0.
S = Set to 1 if bit [31] of the destination register is 1; otherwise set to 0.
V = Set to 1 if the Carry and Sign flags are different; otherwise set to 0.
B = Cleared to 0.
CIRQE = No change.
IRQE = No change.
C 0
src
dst
31 0
src
31 0