5-91
Z380
™
USER'S MANUAL
ZILOG
DC-8297-03
LD
LOAD INTO I OR R REGISTER (BYTE)
LD dst,src dst = I, R
src = A
Operation: dst ← src
The contents of the accumulator are loaded into the destination. Note that the R register does
not contain the refresh address and is not modified by refresh transactions.
Flags: S: Unaffected
Z: Unaffected
H: Unaffected
V: Unaffected
N: Unaffected
C: Unaffected
Addressing Execute
Mode Syntax Instruction Format Time Note
R: LD I,A 11101101 01000111 2
LD R,A 11101101 01001111 2