Zilog Z80180 Manual de usuario Pagina 103

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 326
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 102
Z8018x
Family MPU User Manual
88
UM005003-0703
Refresh Control Register (RCR)
The RCR specifies the interval and length of refresh cycles, while
enabling or disabling the refresh function.
Refresh Control Register (RCR: 36H)
Bit 76543210
Bit/Field REFE REFW ? CYC1 CYC0
R/W R/W R/W ? R/W R/W
Reset 1 1 ? 0 0
Note: R = Read W = Write X = Indeterminate ? = Not Applicable
Bit
Position Bit/Field R/W Value Description
7REFER/W
0
1
REFE: Refresh Enable
Disables the refresh controller
Enables refresh cycle insertion.
6REFWR/W
0
1
Refresh Wait (bit 6)
Causes the refresh cycle to be two clocks in duration.
Causes the refresh cycle to be three clocks in duration by
adding a refresh wait cycle (TRW).
1
0CYC10R/W Cycle Interval — CYC1 and CYC0 specify the interval
(in clock cycles) between refresh cycles. In the case of
dynamic RAMs requiring 128 refresh cycles every 2 ms
(or 256 cycles in every 4 ms), the required refresh interval
is less than or equal to 15.625 ms. Thus, the underlined
values indicate the best refresh interval depending on
CPU clock frequency. CYC0 and CYC1 are cleared to 0
during RESET. Refer to Table 11.