Zilog Z80180 Manual de usuario Pagina 37

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 326
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 36
Z8018x
Family MPU User Manual
22
UM005003-0703
Figure 12. Memory Read/Write (with Wait State) Timing Diagram
I/O Read/Write Timing
I/O Read/Write operations differ from memory Read/Write operations in
the following three ways:
The IORQ (I/O Request) signal is asserted Low instead of the MREQ
signal
The 16-bit I/O address is not translated by the MMU
A16–A19 are held Low
At least one Wait State (TW) is always inserted for I/O read and write
cycles (except internal I/O cycles).
Figure 13 illustrates I/O read/write timing with the automatically inserted
Wait State (TW).
T1 T1T2 TW T3 T2 T3
Phi
A0
A19
D0
D7
WR
MREQ
RD
WAIT
Read Cycle
Write Cycle
TW
Read data
Write data
Vista de pagina 36
1 2 ... 32 33 34 35 36 37 38 39 40 41 42 ... 325 326

Comentarios a estos manuales

Sin comentarios