135
ASCI0 Extension Control Register (I/O Address: 12H) (Z8S180/L180-Class Processors
Only)
Bit 76543210
Bit/Field RDRF
Int
Inhibit
DCD0
Disable
CTS0
Disable
X1 Bit
Clk
ASCI0
BRG0
Mode
Break
Feature
Enable
Break
Detect
(RO)
Send
Break
R/W R/W R/W R/W R/W R/W R/W R/W R/W
Reset 0 00 00 00 0
Note: R = Read W = Write X = Indeterminate ? = Not Applicable
Bit
Position Bit/Field R/W Value Description
7RDRF
Interrupt
Inhibit
R/W 0
1
RDRF Interrupt Inhibit On
RDRF Interrupt Inhibit Off
6DCD0
Disable
R/W 0
1
DCD0 Auto-enables Rx
DCD0 advisory to SW
5CTS0
Disable
R/W 0
1
CTS0 Auto-enable Tx
CTS0 advisory to SW
4X1 Bit
Clk
ASCI0
R/W 0
1
CKA0 /16 or /64
CKA0 is bit clock
3BRG0
Mode
R/W 0
1
As S180
Enable 16-bit BRG counter
2 Break
Feature
Enable
R/W 0
1
Break Feature Enable On
Break Feature Enable Off
1 Break
Detect
(RO)
R/W 0
1
Break Detect On
Break Detect Off