Zilog Z80180 Manual de usuario Pagina 290

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 326
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 289
Z8018x
Family MPU User Manual
274
UM005003-0703
RETI (Z)
MC1 T1T2T3 1st Op Code
Address
1st Op
Code
010 1 0*5
1
10
MC2 T1T2T3 2nd Op Code
Address
2nd Op
Code
010 1 0*5
1
11
MC3
~MC5
TiTiTi * Z 1 1 1 1 1*5
1
11
MC6 T1T2T3 1st Op Code
Address
1st Op
Code
010 1 0*5
0
11
MC7 Ti * Z 111 1 1*5
1
11
MC8 T1T2T3 2nd Op Code
Address
2nd Op
Code
010 1 0*5
0
11
MC9 T1T2T3SP data 010 1 1*5
1
11
MC10 T1T2T3 SP+1 data 0 1 0 1 1*5
1
11
RLCA
RLA
RRCA
RRA
MC1 T1T2T3 1st Op Code
Address
1st Op
Code
010 1 01 0
RLC g
RL g
MC1 T1T2T3 1st Op Code
Address
1st Op
Code
010 1 01 0
RRC g
RR g
SLA g
SRA g
SRL g
MC2 T1T2T3 2nd Op Code
Address
2nd Op
Code
010 1 01 1
MC3 Ti * Z 111 1 11 1
*5 The upper and lower data show the state of M1 when IOC = 1 and IOC = 0 respectively.
Table 51. Bus and Control Signal Condition in Each Machine Cycle (Continued)
Instruction
Machine
Cycle States Address Data RD WR MREQ IORQ M1 HALT ST
Vista de pagina 289
1 2 ... 285 286 287 288 289 290 291 292 293 294 295 ... 325 326

Comentarios a estos manuales

Sin comentarios